Retractable Sensor Cables for Thermocouples, RTDs and Thermistors |
|
|
|
|
|
Retractable Sensor Cables for Thermocouples, RTDs and Thermistors
Cliquer l'image pour l'agrandir
|
|
|
 |
 |
J, K, T and E Thermocouple Calibrations and 3-Wire Copper for RTD's and Thermistors |
 |
Expansion Ratio up to 500%, 300 mm of Cable Stretches to 1.5 metres |
 |
TPE Plastic Insulation for Indoor and Outdoor Use to 100°C |
 |
Retracted Coil Lengths of 30, 60, 90 and 120 cm with 150 mm Straight Ends |
|
|
|
 |
OMEGA® Retractable Sensor Cable is colour coded and spring coiled, for use with thermocouples, RTD's and thermistors.
To achieve a superior jacket construction, OMEGA has employed the latest in insulating material: TPE (thermoplastic elastomer), a unique family of thermoplastics which exhibits characteristics previously found only in rubber compounds. TPE is extremely tough and flexible, and has excellent abrasion resistance. Our special construction technique yields an expansion rate of up to 500%.
OMEGA's retractable sensor cables are specifically recommended for use with electronic-type indicators, either panel, handheld or bench type models. Retractable sensor cables have hundreds of applications: oscillating machinery, handheld surface probes, or wherever retractable sensor cables are required.
Colour Code of Cables and Alloys Used
| Cable Type |
Conductor Alloys |
ANSI Colour Code |
IEC Colour Code |
| Jacket |
+Insulation |
–Insulation |
Jacket |
+Insulation |
–Insulation |
| J | Iron/Constantan | Black | White | Red | Black | Black | White |
| K | Chromel/Alumel | Yellow | Yellow | Red | Green | Green | White |
| T | Copper/Constantan | Blue | Blue | Red | Brown | Brown | White |
| E | Chromel/Constantan | Purple | Purple | Red | Purple | Purple | White |
| RTD/TH | Copper (3-Wire) | White | 2 Black 1 Red | White | 2 Black 1 Red |
Typical Resistance of Cables
| Ohms Per 30 cm of Coiled (150 cm Extended) Cable |
| J | K | T | E | RTD and Thermistor (per Conductor) |
| 16.3 | 27.5 | 14 | 33.1 | 0.57 |
Cable End Termination Options
| Reference |
Description |
| 0 |
25 mm Stripped Ends |
| 1 |
Compensated Spade Lugs |
| 2 |
Standard Thermocouple Plug (OSTW-M) |
| 3 |
Standard Thermocouple Socket (OSTW-F) |
| 4 |
Mini Thermocouple Plug (SMPW-M) |
| 5 |
Mini Thermocouple Socket (SMPW-F) |
| 6 |
RTD 3-pin Standard Socket (OTP-F) |
| 7 |
RTD 3-pin Standard Plug (OTP-M) |
| 8† |
RTD 3-pin Round Socket (TA3-FL) |
| 9† |
RTD 3-pin Round Plug (TA3-ML) |
| 10 |
RTD 3-pin Mini Socket (MTP-F) |
| 11 |
RTD 3-pin Mini Plug (MTP-M) |
| Model No. |
Input Type |
O.D. mm |
| RSC-(1)-(2)-(3)-(4) | T/C | 4.2 mm |
| RSC-RTD-(2)-(3)-(4) | RTD | 4.4 mm |
| RSC-TH-(2)-(3)-(4) | TH | 4.4 mm |
| RSCM*-(1)-(2)-(3)-(4) | T/C | 3.4 mm |
How To Order
1. Fill the 1st box (1) with desired thermocouple type and colour code. Use symbols “JI”, “KI”, “TI”, “EI” for IEC Colour-coded thermocouple types,
“J”, “K”, “T”, “E” for ANSI colour-coded thermocouple types; “RTD” for RTD/Pt100/Pt1000; or “TH” for thermistor.
2. Fill in 2nd box (2) with retracted coil length: 1 = 30cm, 2 = 60cm, 3 = 90cm, 4 = 1.2m
3. Fill in 3rd box (3) with termination style number (one end).
4. Fill in 4th box (4) with termination style number (other end).
* M = Miniature Retractable Cable
† Indicate associated meter or pin out desired for connector
|
 |
|
|
|
Exemple de commande: (1) RSC-KI-30-4-5 Type K IEC colour-coded retractable sensor cable, 30cm long with a mini thermocouple plug at one end and a mini socket at the other end = EUR 14,75
|
|
|
 |
| Constructeur de référence |
|
|
| Utilisez notre constructeur de référence pour personnaliser votre sélection de produit. |
|
|
|
Options
|
|
(1)
|
Cable Type
|
| |
Sélectionner RSC Pour Retractable sensor cable RSCM Pour Miniature retractable sensor cable
|
|
(2)
|
Input Type
|
| |
Sélectionner JI Pour Type J IEC colour-code thermocouple KI Pour Type K IEC colour-code thermocouple TI Pour Type T IEC colour-code thermocouple EI Pour Type E IEC colour-code thermocouple J Pour Type J ANSI colour-code thermocouple K Pour Type K ANSI colour-code thermocouple T Pour Type T ANSI colour-code thermocouple E Pour Type E ANSI colour-code thermocouple RTD Pour Resistance temperature dector TH Pour Thermistor
|
|
(3)
|
Retracted Length
|
| |
Sélectionner 30 Pour 30 cm (IEC only) 60 Pour 60 cm (IEC only) 90 Pour 90 cm (IEC only) 120 Pour 120 cm (IEC only) 1 Pour 1 ft (ANSI only). 2 Pour 2 ft (ANSI only) 3 Pour 3 ft (ANSI only) 4 Pour 4 ft (ANSI only)
|
|
(4)
|
Termination Style (End #1)
|
| |
Sélectionner 0 Pour Trimmed Ends(standard) 1 Pour Spade Lugs 2 Pour OST-M(Male) 3 Pour OST-F(Female) 4 Pour SMP-M(Male) 5 Pour SMP-F(Female) 6 Pour OTP-F(Female-Thermistor and RTD only) 7 Pour OTP-M(Male-Thermistor and RTD only) 8 Pour TA3-FL(Female-Thermistor and RTD only) 9 Pour TA3-ML(Male-Thermistor and RTD only) 10 Pour MTP-F(Female-Thermistor and RTD only) 11 Pour MTP-M(Male-Thermistor and RTD only)
|
|
(5)
|
Termination Style (End #2)
|
| |
Sélectionner 0 Pour Trimmed Ends(standard) 1 Pour Spade Lugs 2 Pour OST-M(Male) 3 Pour OST-F(Female) 4 Pour SMP-M(Male) 5 Pour SMP-F(Female) 6 Pour OTP-F(Female-Thermistor and RTD only) 7 Pour OTP-M(Male-Thermistor and RTD only) 8 Pour TA3-FL(Female-Thermistor and RTD only) 9 Pour TA3-ML(Male-Thermistor and RTD only) 10 Pour MTP-F(Female-Thermistor and RTD only) 11 Pour MTP-M(Male-Thermistor and RTD only)
|
Note: Quelques combinaisons pourraient ne pas être valides, veuillez vérifier avec la notice technique pour les codes d'articles valides.
|
|
|
|
 |
|
Fiche technique
, Produits liés
|
|
|
|
Fiche technique
|
Télécharger Fiche technique produit (RSC_RSM_CABLE.pdf)
|
|
Produits liés
|
Télécharger Fiche technique produit (TC_GEN_SPECS_REF.pdf) - General Thermocouple Specifications |
|
|
|
 |
|
Mots clés: RSC and RSCM Series Retractable Sensor Cables for Thermocouples, RTDs and Thermistors
|
|
|