€1 557,29 OM-CP-OCTTCTEMP2000-A2
                            
                            
                            Déscription
The OM-CP-QUADTCTEMP2000-A2 and OM-CP-OCTTCTEMP2000-A2 are four and eight channel thermocouple data loggers with an LCD screen. The device features on-screen minimum, maximum and average statistics, as well as a user configurable screen that allows for any combination of channels to be displayed. The device accepts J, K, T, E, R, S, B and N type thermocouples.
The OM-CP-QUADTCTEMP2000-A2 and OM-CP-OCTTCTEMP2000-A2 are ideal for a variety of applications, whether it is remote temperature monitoring, or multiple points in a central location. Data from all channels is simultaneously logged and displayed on-screen for real-time monitoring. It can then be downloaded to a PC for further analysis.
| INTERNAL CHANNELS | |
|---|---|
| Temperature Range | -20 °C to +60 °C (-4 °F to +140 °F) | 
| Temperature Resolution | 0.01 °C (0.018 °F) | 
| Calibrated Accuracy | ±0.5 °C (0 °C to 50 °C) ±0.9 °F (32 °F to 131 °F)  | 
              
           
| REMOTE CHANNELS | |
| Remote Channel Thermocouple Types | J, K, T, E, R, S, B, N | 
| Thermocouple Connection | Female subminiature (SMP) | 
| Cold Junction Compensation | Automatic, based on internal channel | 
| Maximum Thermocouple Resistance | 1000 Ω, <100 Ω recommended | 
| REMOTE CHANNELS | |||
|---|---|---|---|
| Thermocouple | Range (°C) | Resolution | Accuracy* | 
| J | -210 to +760 | 0.1 °C | ±0.5 °C | 
| K | -270 to +1370 | 0.1 °C | ±0.5 °C | 
| T | -270 to +400 | 0.1 °C | ±0.5 °C | 
| E | -270 to +980 | 0.1 °C | ±0.5 °C | 
| R | -50 to +1760 | 0.5 °C | ±2.0 °C | 
| S | -50 to +1760 | 0.5 °C | ±2.0 °C | 
| B | +50 to +1820 | 0.5 °C | ±2.0 °C | 
| N | -270 to +1300 | 0.1 °C | ±0.5 °C | 
*Thermocouple accuracy specified with 24 AWG diameter thermocouple wires.
| GENERAL | |
|---|---|
| Memory (All channels enabled)  | 
                4-channel: 524,032 readings per channel 8-channel: 262,016 readings per channel  | 
                     
| Start Modes | Software programmable immediate start or delay start, up to 6 months in advance  | 
                
               
             
| Real Time Recording | May be used with PC to monitor and record data in real time  | 
        
       
     
| LEDs | 1 per channel and 2 status LEDs | 
| Reading Rate | 4 Hz up to 1 reading every 24 hours | 
| Calibration | Digital calibration through software | 
| Calibration Date | Automatically recorded within device | 
| Battery Type | 9 V lithium included, user replaceable | 
| Battery Life | 18 months typical with display off.  3 months typical with continuous display use.  | 
| Data Format | Date and time stamped °C, °F, K, °R, mV, V | 
| Time Accuracy | ±1 minute/month | 
| Computer Interface | USB-A to micro USB cable (included);
         460,800 baud  | 
| Operating System Compatibility  | 
        
    Windows XP SP3/7/8/10 | 
| Software Compatibility | Standard Software version 4.2.21 or later Secure Software version 4.2.18 or later  |     
   
| Operating Environment | -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing  | 
      
| Dimensions | 4-channel: 7.25 in x 2.70 in x 1.22 in (184.15mm x 65.58 mm x 30.99 mm) 8-channel: 7.25 in x 2.70 in x 1.68 in (184.15mm x 65.58 mm x 42.672 mm)  | 
          
| Weight | 4-channel: 15.3 oz (435 g) 8-channel: 20.1 oz (569 g)  | 
                  
| Enclosure | Black anodized aluminum | 
| Approvals | CE | 
Logiciel: